Q Series

Max Flow

45 LPM (12 GPM)

Max Temperature

203 °F (95 °C)

Max Pressure

60 PSIG (0.41 MPa)

Certifications

CE, Semi S2 & S8

Applications

Semiconductor/Electronics
LED/Flat Panel
Solar
Chemical Processing
Aerospace

Description

  • MTBF >20,000 hours
  • redundant safety features
  • LCD color touch screen display
  • +/- 3° C accuracy
  • no standby flow required
  • high purity flow path made of GE214 quartz
  • crevice-free flow path means no bacteria growth or purging required
  • multiple voltage and kilowatt options
  • customizable configuration for power, space, fluid connections and other process needs
  • remote control options
  • overheating controls and warnings
  • standard safety features (EMO, over pressure relief, low liquid level detection, etc.)
Power/Voltage

  • 30kW to 216kW
  • 208V, 380V, 415V, 480V
Configuration Options

  • rolling casters
  • seismic brackets
  • high temperature
  • custom options available
Communication Options

  • ModBus / TCP
  • ModBus / RTU
  • Device Net
Sizing Formula

In order to determine which heater size is needed, calculate the required kilowatt with the following formula:

                Required kW = 0.264 * (Flow in GPM) * (Temperature Delta in °C)

                Example

                Ambient Water Temperature = 25° C

                Desired Process Temperature = 70° C

                Temperature Delta = 45° C

                Required kW = 0.264 * (4 GPM) * (45° C) = 47.5kW

For optimal temperature response and to compensate for seasonal changes in ambient water temperature, we recommend adding 20% excess heating capacity.

                47.5kW * (1.2) = 57kW

                The best option for this application is a 60kW heater.